Input Specifications
|
|
Input range
|
85 VAC to 264VAC
120 VDC to 370 VDC
|
Frequency
|
47 - 440 Hz
|
Inrush current
|
<38 A peak
|
Efficiency
|
75% typical at full load
|
Power factor
|
0.99 typical, meets EN61000-3-2
|
EMI filter
|
Meets FCC Class B CISPR 22 Class B (includes EN55022 class B and VDE 0878 PT3 class B)
|
Electromagnetic compatibility
|
Meets IEC801-2 level 3, IEC801-4 level 3 and IEC801-5 level 3
|
Safety ground leakage current
|
< 0.5mA @50/60Hz, 264VAC input
|
Output Specifications
|
|
Maximum wattage
|
250W
|
Adjustment range
|
± 5% on main
5 - 25V on output 4
|
Cross regulation
|
±2% on output 1
±3% on outputs 2, 3 & 4
|
Hold-up time
|
20 ms at 250W load and 115 VAC nominal line
|
Overload protection
|
Short circuit protection on all outputs. Auto recovery. Over current limit on each output 5 to 45% above peak rated output.
|
Overvoltage protection
|
5V output: 6.0 to 6.7 Vdc. Output 4: 10% to 25% above output voltage setting. Recycle AC to reset.
|
Supervisory output
|
5V / 100mA regulated; output maintained when main outputs inhibited. (for use with inhibit and power good function)
|
Fan supply output
|
12V / 200mA; output maintained when power supply inhibited.
|